TitleProduct

O2 Oxygen Analyzer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2020-08-24 00:42

  • Browse the number:

    444

Send an inquiries
+
Woshilong Instrument (Beijing)Co., Ltd
Contactaixin:

woshilong(Mr.)  

Email:

telephone:

+86-029-8861 0736

phone:

Arrea:

Beijing

Address:

No.9 Shuangyuan Rd, Shijingshan District hi-tech park, Beijing.

Website:

http://www.wslinstrument.com/ http://woshilong.feiongteji.com/

+

Description

WSLY Series O2 Oxygen Analyzer is a new generation of industrial oxygen content analyzer.
During the combustion process of combustion equipment such as boilers and kilns, O2 oxygen analyzer are used to monitor and control combustion, that to provide valuable measurements in realize low oxygen combustion, reduce environmental pollution, process quality.


Application
The O2 Oxygen Analyzer can be widely used in metallurgy, electronics, petrochemical, skewer, glass, building materials, magnetic materials and oxygen production industries. It is an ideal equipment for process control and product testing.


Main Features
★ Easy Operation.
★ Easily replaceable zirconia element.
★ IP67 enclosure.
★ Fast response and easy to operate by functional key.


Specification

Items

Specifications

Oxygen concentration:

0.001~100 vol%

Output signal:

4~20mA DC (maximum load resistance 750Ω)

Setting range:

0~20.6 vol% (0~30% can be set)

Digital communications:

Support Modbus 232/485 and Ethernet (selectable)

Heating time:

Approx. 20 min.

Repeatability:

±0.5vol% maximum value of set range.

Zero drift:

1.5 vol% maximum value of set range (60 days)

Response time:

Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing).

Power supply:

220±10%VAC

Installation:

Flange mounting

Limit output:

Provide settable upper and lower limit outputs (optional)

Temperature control accuracy:

0~700℃ (Floating temperature calculation)

Equipment system accuracy:

±1%F.S.

Digit display mode:

4 bit LED nixie tube display

Operation:

Menu button operation

Calibration operation:

Three parameters on-line calibration

Equipment power:

Approx. 10W (Excluding heating power)

Heating power:

50W (average), able to supply maximum 150W power output

Environmental conditions:

Ambient temperature 0~70℃, relative humidity ≤ 90%

Protection level:

IP65

Electrical interface:

M20

Explosion-proof level:

EXdII ct6 GB (only for explosion-proof type product)


Detector length:

180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)

(Note: Detector length is from the detector tip to flange)

http://www.wslinstrument.com/